Obround Stepped Quartz Window, HCL Handling
Window made from a block of GE-124 quartz, PN100793
The sight glass will be installed on pressure vessels with internal rubber lining therefore the steel part of the sight glass will also be rubber lined. Thus, a common forged carbon steel material such as SA105, or SA350 LF.2 is sufficient. The transparent part shall be exposed to the chemical agent and shall be able to withstand 13% concentration of HCL and/or 13% concentration of NAOH.
This window is polished to S-D 60-40 on all flat sides. Product development for a customer in energy applications, Greece.
Design Specifications:
- Hydrotest Pressure 21 Barg
- Design Pressure 14 Barg
- Design Temperature 80°C